Home | Profile | Products | Contact | Enquiry
 
Single Point Load Cell
 
Single Point Load Cell Model 38840
   
Other Models
 
 
  Model Information :  
 
   

 
     
 
Dimension Specifications
Standard Capacities
100,150,200,300,500,750,1000,1500-Kgf
Excitation Voltage
10VDC-Max. 15 VDC
Nominal Output
2.0 mV/V
Non-Linearity
<±0.025% FSO
Hysteresis
<±0.01% FSO
Non-Repeatability
<±0.02% FSO
Creep (30 Minutes)
<±0.03% FSO
Zero Balance
±1.0% FSO
Input Resistance
390±15 Ohms
Output Resistance
350±5 Ohms
Insulation Resistance (50VDC)
> 1000 Mega Ohms
Cable Length (4 Crore Screened)
250 Cm
Safe Overload of Rated Capacity
150%
Ultimate Overload of Rated Capacity
250%
Allowable Side Load
-
Side Load Discrimination
-
Temp Compensated Range
0-60ºC
Temperature Effect on Output
<0.0015% FSO /ºC
Temperature Effect on Zero
<0.0020% FSO /ºC
Platter Size
750mm*750mm
Eccentric Load Effect
<0.02% of FSO at 1/3
Rated load Placed within
the specified sized platter

Deflection
<0.5mm at FSO
Tightening Torque
5 m.kg
Finish & Construction
Electroless Nickel Plated Steel Alloy
Environmental Protection Class
lp65
Applications
  • Medium Platform Scales
  • Bag Weighers
  • hopper Weighers
FSO=Full Scale Output
 
 
 
 
   Contact
     
  GPS Sensors & Indicators Pvt. Ltd.
K-14, Udyog Nagar
Peera Garhi
New Delhi 110041
Tel.: 91-11-45604444
E-Mail : sales@loadcells.in
 
     
     
 